Print this page.

Festool Kit for Kapex Compound Miter Saw mexico-flag-button-36w.jpg quebec-flag_button-w36.jpg

 

Installation

Kapex saw (Fig. 1) should be mounted on a Festool table or other support.

Illustrations show the saw used with the Festool table and accessories.

Steps

  1. Use two M5x12 flathead bolts and 2 M5 T-nuts to fasten one bench mount bracket (Fig. 5) into the channel on the crown stop base extension (Fig. 2).

  2. If you have a Festool guide arm, attach another bracket to the end of it (Fig. 4).

  3. The SawGear support leg includes a third bracket. Make sure all brackets are approximately in line.

  4. Lay SawGear across the brackets in the desired position relative to the saw.

  5. Pivot SawGear, so the curled front edge of the brackets fits in the full length slot at the lower back of the measuring bar.

  6. Lay SawGear flat against the surface of the brackets so the beveled back lip of the measuring bar can be secured by the knobs.

  7. Turn the locking knobs to secure SawGear in the brackets. Make sure to tighten the adjustment knob on the crown stop base extension (Fig. 3) as well.

561287-Left.jpg

Fig. 1

Kapex KS 120 EB

Compound Sliding Miter Saw

step-04.jpg

Fig. 2

Attach one bracket to the Crown Stop using a 2 bolts and T-nuts.

crownstop-base.jpg

Fig. 3

Crown Stop Base Extension needed to attach SawGear to the setup.

step-05.jpg

Fig. 4

Attach another bracket to an optional extension guide arm for extra support of  the SawGear measuring bar.

bench_mount_bracket.jpg

Fig. 5

SawGear includes two bench mount brackets. A  third comes with the leg.

step-03.jpg

Fig. 6

SawGear attaches to the adjustable support leg.

NOTE: Using the Festool crown stop base extension to support the SawGear bench mount bracket will prevent the saw from pivoting to a full 60° position. To cut angles of 60° the SawGear must be temporarily moved out from the Kapex saw.